Ships contracted for construction on or after 1 July 2024 must meet class requirements for cyber resilience. This guide explains what E26 and E27 require, who delivers which documents and what existing fleets should do now.

Request consultation

What are IACS UR E26 and E27?

The International Association of Classification Societies (IACS) issues Unified Requirements (URs): minimum requirements that all member societies incorporate into their class rules. Individual societies may set stricter requirements.

UR E26, “Cyber resilience of ships”, treats the ship as a single entity: how computer-based systems (CBS) on board are inventoried, protected and monitored, and how the crew responds to an incident and restores operations. UR E27, “Cyber resilience of on-board systems and equipment”, works one level down and defines the security capabilities and documentation an individual system or piece of equipment must provide.

The original versions of both URs, published in April 2022, were withdrawn before they could enter into force on 1 January 2024. The applicable texts are the complete revisions, Rev.1 (E27: September 2023; E26: November 2023).

Scope: which ships

IACS societies apply Rev.1 uniformly to ships contracted for construction on or after 1 July 2024, meaning the date the building contract is signed between the prospective owner and the shipbuilder. It is mandatory for:

  • Passenger ships (including passenger high-speed craft) engaged in international voyages
  • Cargo ships of 500 GT and upwards engaged in international voyages
  • High-speed craft of 500 GT and upwards engaged in international voyages
  • Mobile offshore drilling units of 500 GT and upwards
  • Self-propelled mobile offshore units engaged in construction, such as wind turbine installation vessels

Other vessels and systems in scope

For other vessels, such as cargo ships below 500 GT, fishing vessels or pleasure yachts not engaged in trade, the URs serve as non-mandatory guidance. Owners of existing ships can also use them voluntarily.

E26 covers operational technology (OT) on board whose compromise could endanger people, the ship or the environment: propulsion, steering, anchoring and mooring, power generation and distribution, fire detection and extinguishing, bilge, ballast and loading computer, watertight integrity, lighting and required safety systems. Navigation and communication systems required by regulation are also included. In addition, E26 applies to any IP-based interface between these systems and other networks, for example administrative networks, crew welfare Wi-Fi or passenger networks.

Who must deliver what?

E26 spreads the evidence across the ship’s life cycle and across three parties.

Suppliers (E27)

For each system in scope: CBS asset inventory, topology diagrams, description of security capabilities, test procedure, secure development life cycle documents, maintenance and verification plans, and information supporting the owner’s incident response and recovery plans. Documents are submitted to the classification society; a type approval certificate covering the security capabilities can replace the survey.

Systems integrator / yard (E26)

During design and construction: approved supplier documentation, zones and conduit diagram, cyber security design description, vessel asset inventory and, where systems are excluded, a risk assessment with compensating countermeasures. At commissioning: the ship cyber resilience test procedure, demonstrated to the society.

Shipowner (E26)

Takes over and maintains the documentation and submits the ship cyber security and resilience program. It covers management of change, software updates, firewalls, malware protection, access and remote access, mobile and portable devices, anomaly detection, and incident response and recovery plans. Implementation is demonstrated at the first annual survey and then at annual and special surveys.

The five requirement areas of E26

E26 organises its requirements under Identify, Protect, Detect, Respond and Recover. In practice this means a complete hardware and software inventory, segmentation into security zones with controlled boundaries, network protection, malware protection, access control, secured wireless communication, controlled remote access, rules for mobile and portable devices, anomaly detection, incident response plans and the ability to shut down, reset and restore systems in a controlled way.

Remote access rules are particularly specific: systems in scope must not expose any IP address to untrusted networks. Communication over such networks, including satellite and internet links, requires secure tunnels with endpoint authentication and encryption. Remote access must only be possible after explicit acceptance by a responsible person on board, and all remote access events must be logged. This directly affects how Starlink and VSAT systems are planned.

Relation to IMO MSC-FAL.1/Circ.3 and IEC 62443

The IMO Guidelines on maritime cyber risk management (MSC-FAL.1/Circ.3, currently Rev.4 dated 28 May 2026) give high-level recommendations organised around the functional elements Govern, Identify, Protect, Detect, Respond and Recover. IMO Resolution MSC.428(98), adopted in June 2017, encourages administrations to ensure that cyber risks are addressed in safety management systems under the ISM Code no later than the first annual verification of the company’s Document of Compliance after 1 January 2021.

The difference: the IMO texts address the company and its management system, while E26 and E27 are technical class requirements for newbuildings and equipment. In practice they interlock. E26 explicitly notes that access control procedures for safety-critical assets may be included in the Ship Security Plan (ISPS) and the SMS (ISM).

The security capabilities in E27 are based on selected requirements of IEC 62443-3-3, and its secure development requirements reference IEC 62443-4-1. Organisations that already align their processes with IEC 62443 have a solid starting point.

What existing fleets should do now

E26 and E27 are not mandatory for ships contracted before 1 July 2024. The IMO expectations for the safety management system still apply, and shipping companies established in the EU may also fall under NIS2.

A practical approach is to use E26 as the benchmark for an assessment: build an asset inventory, document the boundaries between IT and OT networks, record vendor remote access paths and review incident response plans. The result is a prioritised action plan that can be kept up to date through later changes, such as retrofitting satellite communications.

Practical checklist

For newbuilding projects and as a reference for existing ships:

  • Check the contract date: does the ship fall under Rev.1 (contract on or after 1 July 2024)?
  • Confirm how your classification society has implemented E26/E27 in its rules
  • Define roles: who is the systems integrator, which suppliers provide E27 documents?
  • Identify systems in scope and build the vessel asset inventory
  • Produce the zones and conduit diagram and separate IT and OT networks
  • Record and secure remote access and all satellite and internet connections
  • Prepare the test procedure for commissioning
  • Set up the ship cyber security and resilience program and link it to the SMS and SSP
  • Establish management of change so documents stay current after modifications

Frequently asked questions

Do E26 and E27 apply to my existing ship?
They are mandatory only for ships whose building contract was signed on or after 1 July 2024. For other ships they serve as non-mandatory guidance.
Who is responsible for E26 compliance?
Responsibility is shared: the systems integrator, usually the yard, provides the design and commissioning documents, suppliers provide E27 documentation for their systems, and the shipowner provides the operational program and demonstrates it at surveys.
Does E26 replace the IMO guidelines?
No. The IMO texts concern the company’s safety management system; E26 and E27 are technical class requirements. They complement each other.
Is a Starlink terminal affected by E26?
E26 applies to IP-based interfaces between systems in scope and other networks. If satellite connectivity is connected to OT systems, for example for remote maintenance, the segmentation and remote access requirements apply.
How does DMG Infotech help?
We align maritime cyber risk processes with IMO requirements and IEC 62443. For an ISO 27001 ISMS we carry out gap analyses and deliver a gap report, risk register and 90-day remediation plan. On board we support network infrastructure and secure IT/OT integration.

Check your E26/E27 readiness

We assess your fleet against E26, IMO requirements and IEC 62443 and deliver a prioritised action plan.